Dynamics of Residual Microflora Growth During Milk Pasteurization — Mathematical Model
Dynamics of Residual Microflora Growth During Milk Pasteurization
Rigorous mathematical derivation of how residual bacterial concentration evolves inside the receiving tank during continuous in-line milk pasteurization when the outlet temperature is maintained at 35–40 °C for calf feeding or cheese vat inoculation.
1. Problem Statement
Consider a continuous in-line pasteurization process in which freshly milked or chilled raw milk with an initial bacterial contamination Binit (CFU/cm3) is pumped into an in-line pasteurizer of flow capacity Q. Inside the heating chamber, the milk is decontaminated at pasteurization temperature Tpast with pasteurization efficiency ηpast (%) down to an initial post-pasteurization residual microflora level Bpast_init. The milk then passes through a counter-current heat recuperator, where it is cooled by incoming raw milk to a final outlet temperature Tfinal and accumulates in a receiving tank until the entire batch is pasteurized.
This exact hydraulic scheme is widely used in cheesemaking (filling a cheese vat at renneting temperature) and in calf feeding (filling a milk taxi or feeding tank at physiological drinking temperature). Our objective is to derive the exact mathematical law governing how the average bacterial concentration of pasteurized milk Bpast_end(t) changes inside the receiving tank throughout the pasteurization cycle.
The mathematical problem is to determine the growth law of bacterial contamination inside receiving tank 6 during the pasteurization process of duration t.
2. Mathematical Formulation & Discretization
In freshly milked raw milk, microflora does not multiply during the first two hours due to the natural bactericidal phase (lactoperoxidase and immunoglobulins). In chilled raw milk (+4 °C), bacterial division is arrested by low temperature. Therefore, we treat the initial bacterial count Binit in raw milk tank 1 as constant throughout the pasteurization run.
At the outlet of the pasteurizer, milk enters receiving tank 6 with an initial residual bacterial concentration equal to:
The temperature of pasteurized milk Tfinal in receiving tank 6 is maintained within 35–40 °C, as this is the optimal physiological temperature for feeding calves and for adding starter cultures in cheesemaking. Simultaneously, 35–40 °C is the optimal temperature window for the rapid multiplication of surviving residual microflora.
Bacterial cells reproduce by binary fission (dividing in two). If the average cell division period (generation time) equals A minutes, then A is the doubling time of bacterial concentration in milk, and the growth dynamics of a static portion of residual microflora follows the exponential law:
However, receiving tank 6 is filled continuously rather than all at once. Let us divide the total pasteurization duration t into n small discrete time intervals of length Δt:
where n is the number of discrete time intervals into which the duration t is partitioned.
Consider first a pasteurization interval of A minutes, and for clarity set n = A so that each step is Δt = t / n = A / n = 1 min. After A minutes (at t = A), the very first discrete portion of pasteurized milk that entered tank 6 during the first minute (i = 1) has been incubating at 35–40 °C for the full period A and therefore reaches a bacterial concentration of:
Meanwhile, the final portion that entered tank 6 between minute (A − 1) and minute A (i = A) has just arrived and has a bacterial concentration approximately equal to Bpast_init:
For sufficiently large A, the average bacterial contamination of the entire milk volume accumulated in tank 6 over the first A minutes is the arithmetic mean of all A equal-volume portions:
In general form, for any arbitrary pasteurization duration t partitioned into n intervals, the bacterial concentration of the i-th portion at minute t after the start of pasteurization equals:
Consequently, the average bacterial concentration of the entire accumulated volume of pasteurized milk in tank 6 at the end of minute t is:
3. Continuous Limit & Definite Integral Solution
Passing to the continuous limit as the number of partitions approaches infinity (n → ∞ and Δt → 0):
This Riemann sum converges analytically to the closed-form expression:
Note that expression (9) is the discrete form of the integral mean value of the exponential growth function B(t) (Equation 2) over the time interval [0, t]. Writing it directly in continuous integral form yields:
Evaluating the definite integral in (11) with respect to τ from 0 to t and dividing by t yields the exact same analytical formula (10), since (9) and (11) represent the same integral mean of function (2):
4. Practical Evaluation & Engineering Conclusion
At temperatures of 35–40 °C, residual microflora in milk doubles every 15–20 minutes. Based on microbiological reference data (see our companion studies Milk Decontamination Regime for Infrared Pasteurizers and Optimization of Milk Pasteurization Temperature), we adopt a standard doubling period of A = 19 minutes.
Substituting A = 19 min, an initial raw milk bacterial count of Binit = 100,000 CFU/cm3 (105 CFU/cm3), and a pasteurization efficiency of ηpast = 99.9% (so that Bpast_init = 100 CFU/cm3) into Equation (12) gives:
which simplifies numerically to:
By contrast, if tank 6 were filled instantaneously at t = 0 and not continuously diluted with freshly pasteurized milk, the microflora concentration inside it would grow according to the pure exponential equation (2):
As shown in Figure 3, the continuous-filling function Bpast_end(t) (Equation 14) rises more slowly than the static function B(t) (Equation 15) thanks to continuous dilution by incoming pasteurized milk. Nevertheless, within 60 minutes, the residual bacterial count in receiving tank 6 grows by a factor of 3.62 (from 100 to 362 CFU/cm3 when starting at 100 CFU/cm3 post-pasteurization, or from 100,000 to 362,000 CFU/cm3 if starting at 100,000 CFU/cm3 post-pasteurization).
When processing non-grade or mastitic raw milk with an initial contamination of Binit = 5,000,000 CFU/cm3 (5 × 106 CFU/cm3) at 99.9% efficiency (Bpast_init = 5,000 CFU/cm3), the average bacterial count in the receiving tank grows from 5,000 to 18,100 CFU/cm3 in 60 minutes, and escalates to 89,900 CFU/cm3 if pasteurization drags on for 2 hours (120 minutes) — before calf feeding even begins!
Select a Pasteurizer Matched to Your One-Hour Batch Volume
Explore our Calf Milk Pasteurizers and In-Line Infrared Milk Pasteurizers (100 to 3000 L/h) or contact Chief Design Engineer Ruslan Fomin at +380503257808.
View Milk Pasteurizers Next Model: Temperature Optimization