Mon–Sat: 08:00–19:00

Maximizing Batch Pasteurizer Productivity by Minimizing Thermal Cycle Duration — Mathematical Model

26.12.2025
Mathematical Model • Batch Cycle Optimization

Maximizing Batch Pasteurizer Productivity by Minimizing Thermal Cycle Duration

Finding the absolute mathematical minimum of the complete batch pasteurization cycle duration by coupling heat-exchanger thermodynamics with Dahlberg–Cook pathogen inactivation kinetics.

By Ruslan Fomin • Published: December 26, 2025 (Updated: October 19, 2026)

Objective of the Study

The goal of this study is to find the absolute mathematical minimum duration of a complete pasteurization cycle for batch pasteurizers. The classical batch pasteurization regime (65 °C with a 30-minute hold) is a technological holdover that severely restricts equipment throughput. The total time of a pasteurization cycle is formed by three physical stages:

  1. Heating time (theat): Raising the milk from initial temperature to the target pasteurization temperature.
  2. Stationary holding time (thold): Exposure at the target pasteurization temperature.
  3. Cooling time (tcool): Subsequent cooling down to the calf-feeding or fermentation inoculation temperature.

Minimizing total cycle time requires building a comprehensive mathematical model that simultaneously accounts for heat-exchanger thermodynamics and the exponential kinetics of microflora inactivation.

1. Mathematical Model of the Cycle Components

1.1. Stationary Holding Time

The basis for determining the required exposure time is the Dahlberg–Cook equation, which describes the inactivation kinetics of the tuberculosis bacillus (Mycobacterium tuberculosis) in whole milk. The exponential dependence of holding time (in seconds) on pasteurization temperature calibrated across standard reference regimes (65 °C / 30 min; 74 °C / 20 s; 85 °C / 0 s) has the form:

thold(Tpast) = e36.7459 − 0.45 · Tpast
(1)

1.2. Heating Time

The ramp-up duration of the system depends on the applied thermal power and product mass. For a direct-heating batch pasteurizer UZM-200E (power P = 18,000 W, milk mass Mmilk = 200 kg, average specific heat capacity Cmilk ≈ 3,900 J/(kg·°C)), the heating time function (in seconds) is described by the linear equation:

theat(Tpast) = (Tpast − Tmilk0) · Cmilk · MmilkP
(2)

1.3. Cooling Time

Cooling of a batch apparatus obeys the Newton–Richmann law and follows a logarithmic dependence. Based on numerical modeling of the counter-current heat exchanger temperature curve, the cooling time (in minutes) from pasteurization temperature Tpast down to calf-feeding temperature (Tfeed = 40 °C) using cooling water (Twater = 10 °C) is described by the function:

tcool(Tpast) = −125031 · ln(Tfeed − TwaterTpast − Twater)
(3)

2. Optimization and Finding the Extremum of the Function

To find the fastest operating regime, we must find the extremum (minimum) of the composite total-time function combining all three components (converting heating and holding seconds into minutes):

ttotal(Tpast) = theat(Tpast) + thold(Tpast)60 + tcool(Tpast) → min
(4)

Analysis of the behavior of this composite function reveals a fundamental physical conflict between two processes:

  • Raising the pasteurization temperature exponentially shortens the required holding time.
  • Raising the pasteurization temperature linearly increases the heating time and logarithmically stretches the subsequent cooling time.
Calculation in the Mathcad environment identifies two critical points:
  1. If we optimize only the thermal exposure time (heating + holding) while ignoring cooling, the mathematical minimum lies at 71.508 °C.
  2. When we account for the massive logarithmic “cooling tail,” the extremum of the total cycle function shifts downward. The optimal pasteurization temperature that guarantees the shortest overall cycle time is 70.047 °C.

3. Economic Feasibility: Comparison of Regimes

The mathematically proven optimum (70.047 °C) dramatically outperforms the outdated classical regime (65 °C). Let us compile the calculated data into a comparative table:

Cycle Parameter (200 L Batch, 18 kW) Regime 1: Classical Vat Standard Regime 2: Optimized (UZM-E)
Pasteurization Temperature 65 °C 70.047 °C
Heating Time ~44 min ~47.6 min
Holding Time 30 min ~3 min (dynamic)
Cooling Time (to 40 °C) 24.4 min 28.3 min
Total Cycle Time ~98.4 min ~78.9 min (−19.5 min)

Eliminating the stationary 30-minute hold and transitioning to the calculated thermal optimum saves more than 19 minutes of pure machine time on every cycle. Taking into account the reduction in auxiliary operations thanks to UZM-E automation, the real operational gain exceeds 25 minutes per cycle. For a medium-sized dairy enterprise, this means the ability to run one additional full batch per shift without a single dollar of capital investment in expanding the equipment fleet.

Next Engineering Step:
The discovered temperature optimum (70.047 °C) with minimal holding indisputably maximizes apparatus productivity under stationary holding rules. However, from the standpoint of microbiology and the physical chemistry of milk proteins, this calculation is still incomplete, because milk continuously accumulates both microbiological lethality and thermal protein load during ramp-up heating and cooling.
Is an even faster zero-holding regime safe for the product? To prove this, we must move from a simple time balance to integral calculus of thermal impact across the entire curvilinear cycle graph. This is the subject of our next mathematical study: Optimization of Batch Pasteurization Regimes by Microbiological Lethality and Thermal Load Criteria.