Optimization of Batch Pasteurization Regimes by Microbiological Lethality and Thermal Load Criteria
Optimization of Batch Pasteurization Regimes by Microbiological Lethality and Thermal Load Criteria
The material below is the complete mathematical model for the article “Optimization of Milk Pasteurization Regimes in Batch Units: Why Holding Time Is No Longer Needed”.
1. Formulation of the Optimization Problem and Historical Context
The milk pasteurization process in a batch apparatus is a continuous thermodynamic cycle consisting of three phases: heating, holding, and cooling. The impact of the temperature profile T(t) on the product is described by two competing integral indicators that both depend exponentially on temperature, but have different exponent slopes (kinetic parameters):
- Microbiological Lethality (L): The accumulated fraction of destroyed pathogenic microorganisms. Mandatory safety boundary condition: L ≥ 1.
- Chemical Thermal Load (N): The whey protein denaturation index. Objective function: N → min.
Mathematical problem statement: Find the temperature profile T(t), defined by the peak pasteurization temperature Tpast and holding time thold, at which the total chemical damage function Ntotal(Tpast, thold) attains its global minimum subject to the strict safety constraint Ltotal(Tpast, thold) ≥ 1.
2. Constructing the Temperature Profile Functions T(t)
To model the system, we consider a batch milk mass Mmilk = 200 kg, specific heat capacity Cmilk ≈ 3,900 J/(kg·K), initial raw milk temperature Tmilk0 = 4 °C, and cooling water temperature Twater = 10 °C.
Phase 1: Heating (Linear Approximation)
Under direct energy transfer from the heaters (power P = 18,000 W) to an ideally mixed circulating liquid without jacket heat losses, the differential energy balance equation dT/dt = P / (Cmilk · Mmilk) has a linear solution. The temperature function with respect to time t (seconds) is:
The time required to reach the target peak temperature Tpast is:
Phase 2: Cooling (Exponential Decay)
Cooling obeys the Newton–Richmann law. For a high-dynamics rapid cooling loop (as implemented in intensified UZM-E heat exchangers), the solution is described by the classical exponential decay function where the peak temperature Tpast serves as an argument:
3. Finding the Root of the Microbiological Lethality Function
The rate of thermal inactivation of microorganisms is described by the Dahlberg–Cook differential:
To find the absolute mathematical optimum of the system, we apply the zero-holding condition thold = 0. Any positive holding duration thold > 0 widens the area under the temperature curve, monotonically increasing Ntotal. The extremum Ntotal → min lies strictly on the boundary L = 1, where complete decontamination is achieved exclusively via the integrals of the transient processes (heating and cooling).
Total lethality (without stationary holding) is described by the integral equation:
Applying a numerical root-finding method to determine the required peak temperature:
Calculation result: Topt_past = 70.004 °C. This proves that the system possesses sufficient thermal trajectory inertia to guarantee full microbiological lethality L = 1 at a peak of 70.004 °C with zero stationary holding phase (lethality accumulated during heating is 0.518, and during cooling is 0.501; total L = 1.019 ≥ 1).
4. Integrating the Chemical Thermal Load
The rate of whey protein denaturation has a kinetic thermal sensitivity parameter z = 30 °C. The instantaneous chemical damage function is 10[T(t) − 65] / 30. To eliminate mathematical artifacts (accumulation of fictitious damage at room temperatures), integration is performed exclusively in the region above the protein denaturation activation threshold (50 °C).
Integration time limits:
Calculating the chemical thermal load components for the optimum peak 70.004 °C:
Total thermal protein damage of the optimized cycle:
5. Analysis of Boundary Conditions and Heat-Transfer Hydrodynamics of Inertial Vats
To prove the inefficiency of the traditional algorithm, the objective function was evaluated on classical batch vats with a water jacket. The fundamental flaw of classical jacketed vats (where wall thickness is only 1.2–1.5 mm) lies not in “metal mass,” but in fundamental heat-transfer hydrodynamics. In an external continuous-flow heat exchanger (UZM-E), high flow velocity generates a high Reynolds number (Re > 10,000), transitioning the flow into a turbulent regime. This ensures exponential growth of the Nusselt number (Nu) and maximizes convective heat-transfer coefficients (α), bringing the overall heat-transfer coefficient to k ≈ 2,500–3,500 W/(m2·K).
Conversely, in a classical water-jacket vat, fluid velocities near the wall remain minimal even with a mechanical agitator. Flow approaches the laminar regime (low Re), the thermal boundary layer thickens, the Nusselt number drops sharply, and the overall heat-transfer coefficient barely reaches k ≈ 300–500 W/(m2·K). According to our calculations, the thermal and hydrodynamic inertia of the water jacket reduces effective heating power to P ≈ 6,500 W and slows the cooling process by a factor of 2.77 compared to the intensified heat exchanger.
Adapted functions for the inertial classical vat system (P = 6,500 W):
Time limits for the inertial system:
Evaluating the integrals for the inertial classical model (regime 65 °C / 30 min = 1,800 s), where the cooling boundary is tcool_50_classic = root(Tcool_inert(t, 65) − 50, t, 0, 10000) = 2.134 × 103 s (2,134 s):
Total thermal protein damage in the classical water-jacket vat:
6. Conclusions and Hardware Limitations
Analytical and numerical solution of the coupled integro-differential kinetic equations proves that applying a stationary holding phase (thold > 0) in modern direct-heating batch pasteurizers is a mathematically unfounded and technologically destructive step.
The ratio of objective function values Ntotal_classic / Ntotal_opt = 4,099 / 1,351 ≈ 3.03 demonstrates that transitioning from the inertial hydrodynamics of a water jacket (regime 65 °C / 30 min) to an apparatus with intensified direct heat exchange (optimum 70.00 °C / 0 min) achieves a threefold reduction in chemical protein denaturation (and nearly fourfold on the fast empirical cooling curve) at identical 100% microbiological safety.
The massive thermal protein destruction in a classical jacketed vat is generated by its low heat-transfer criteria, which catastrophically stretch the integration limits, and by the artificial 30-minute stationary hold, which accounts for ≈ 44% of total macromolecular denaturation.