Mon–Sat: 08:00–19:00

Optimization of Batch Pasteurization Regimes by Microbiological Lethality and Thermal Load Criteria

04.03.2026
Mathematical Model • Integral Lethality & Protein Preservation

Optimization of Batch Pasteurization Regimes by Microbiological Lethality and Thermal Load Criteria

The material below is the complete mathematical model for the article “Optimization of Milk Pasteurization Regimes in Batch Units: Why Holding Time Is No Longer Needed”.

By Ruslan Fomin • Published: March 4, 2026 (Updated: October 19, 2026)

1. Formulation of the Optimization Problem and Historical Context

The milk pasteurization process in a batch apparatus is a continuous thermodynamic cycle consisting of three phases: heating, holding, and cooling. The impact of the temperature profile T(t) on the product is described by two competing integral indicators that both depend exponentially on temperature, but have different exponent slopes (kinetic parameters):

  1. Microbiological Lethality (L): The accumulated fraction of destroyed pathogenic microorganisms. Mandatory safety boundary condition: L ≥ 1.
  2. Chemical Thermal Load (N): The whey protein denaturation index. Objective function: N → min.
Historical paradox: The traditional batch pasteurization regime of 65 °C / 30 min arose not as the result of chemical kinetics calculations, but as a consequence of the hardware limitations of early 20th-century technology. Early pasteurizers used water or steam jackets with extremely low heat-transfer efficiency and primitive control systems. A prolonged 30-minute hold was the only available engineering workaround to guarantee decontamination of the entire liquid volume given the massive temperature gradients and cold “dead zones” inside primitive tanks. It was a forced compromise between safety and equipment inaccuracy that later became mistakenly entrenched as a “gentle standard.”

Mathematical problem statement: Find the temperature profile T(t), defined by the peak pasteurization temperature Tpast and holding time thold, at which the total chemical damage function Ntotal(Tpast, thold) attains its global minimum subject to the strict safety constraint Ltotal(Tpast, thold) ≥ 1.

2. Constructing the Temperature Profile Functions T(t)

To model the system, we consider a batch milk mass Mmilk = 200 kg, specific heat capacity Cmilk ≈ 3,900 J/(kg·K), initial raw milk temperature Tmilk0 = 4 °C, and cooling water temperature Twater = 10 °C.

Phase 1: Heating (Linear Approximation)

Under direct energy transfer from the heaters (power P = 18,000 W) to an ideally mixed circulating liquid without jacket heat losses, the differential energy balance equation dT/dt = P / (Cmilk · Mmilk) has a linear solution. The temperature function with respect to time t (seconds) is:

Theat(t) = Tmilk0 + PCmilk · Mmilk · t
(1)

The time required to reach the target peak temperature Tpast is:

theat(Tpast) = (Tpast − Tmilk0) · Cmilk · MmilkP
(2)

Phase 2: Cooling (Exponential Decay)

Cooling obeys the Newton–Richmann law. For a high-dynamics rapid cooling loop (as implemented in intensified UZM-E heat exchangers), the solution is described by the classical exponential decay function where the peak temperature Tpast serves as an argument:

Tcool(t, Tpast) = Twater + (Tpast − Twater) · e−0.0248 · (t / 60)
(3)

3. Finding the Root of the Microbiological Lethality Function

The rate of thermal inactivation of microorganisms is described by the Dahlberg–Cook differential:

dL = e−[36.7459 − 0.45 · T(t)] dt
(4)

To find the absolute mathematical optimum of the system, we apply the zero-holding condition thold = 0. Any positive holding duration thold > 0 widens the area under the temperature curve, monotonically increasing Ntotal. The extremum Ntotal → min lies strictly on the boundary L = 1, where complete decontamination is achieved exclusively via the integrals of the transient processes (heating and cooling).

Total lethality (without stationary holding) is described by the integral equation:

Ltotal(Tpast) = theat(Tpast)∫0 e−[36.7459 − 0.45 · Theat(t)] dt  +  tcool_max∫0 e−[36.7459 − 0.45 · Tcool(t, Tpast)] dt
(5)

Applying a numerical root-finding method to determine the required peak temperature:

Topt_past = root(Ltotal(Tpast) − 1, Tpast, 65, 75) = 70.004 °C
(6)

Calculation result: Topt_past = 70.004 °C. This proves that the system possesses sufficient thermal trajectory inertia to guarantee full microbiological lethality L = 1 at a peak of 70.004 °C with zero stationary holding phase (lethality accumulated during heating is 0.518, and during cooling is 0.501; total L = 1.019 ≥ 1).

4. Integrating the Chemical Thermal Load

The rate of whey protein denaturation has a kinetic thermal sensitivity parameter z = 30 °C. The instantaneous chemical damage function is 10[T(t) − 65] / 30. To eliminate mathematical artifacts (accumulation of fictitious damage at room temperatures), integration is performed exclusively in the region above the protein denaturation activation threshold (50 °C).

Integration time limits:

theat_50 = (50 − Tmilk0) · Cmilk · MmilkP,    tcool_50(Tpast) = root(Tcool(t, Tpast) − 50, t, 0, 2000)
(7)

Calculating the chemical thermal load components for the optimum peak 70.004 °C:

Nheat = theat(70.004)∫theat_50 10[Theat(t) − 65] / 30 dt = 650.412,    Nhold = 0
(8)
Ncool = tcool_50(70.004)∫0 10[Tcool(t, 70.004) − 65] / 30 dt = 700.588
(9)

Total thermal protein damage of the optimized cycle:

Ntotal_opt = Nheat + Nhold + Ncool = 650.412 + 0 + 700.588 = 1.351 × 103 units (1,351 units)
(10)

5. Analysis of Boundary Conditions and Heat-Transfer Hydrodynamics of Inertial Vats

To prove the inefficiency of the traditional algorithm, the objective function was evaluated on classical batch vats with a water jacket. The fundamental flaw of classical jacketed vats (where wall thickness is only 1.2–1.5 mm) lies not in “metal mass,” but in fundamental heat-transfer hydrodynamics. In an external continuous-flow heat exchanger (UZM-E), high flow velocity generates a high Reynolds number (Re > 10,000), transitioning the flow into a turbulent regime. This ensures exponential growth of the Nusselt number (Nu) and maximizes convective heat-transfer coefficients (α), bringing the overall heat-transfer coefficient to k ≈ 2,500–3,500 W/(m2·K).

Conversely, in a classical water-jacket vat, fluid velocities near the wall remain minimal even with a mechanical agitator. Flow approaches the laminar regime (low Re), the thermal boundary layer thickens, the Nusselt number drops sharply, and the overall heat-transfer coefficient barely reaches k ≈ 300–500 W/(m2·K). According to our calculations, the thermal and hydrodynamic inertia of the water jacket reduces effective heating power to P ≈ 6,500 W and slows the cooling process by a factor of 2.77 compared to the intensified heat exchanger.

Adapted functions for the inertial classical vat system (P = 6,500 W):

Theat_inert(t) = Tmilk0 + 6500Cmilk · Mmilk · t,    Tcool_inert(t, Tpast) = Twater + (Tpast − Twater) · e−(0.0248 / 2.77) · (t / 60)
(11)

Time limits for the inertial system:

theat_inert_50 = (50 − Tmilk0) · Cmilk · Mmilk6500,    theat_inert(Tpast) = (Tpast − Tmilk0) · Cmilk · Mmilk6500
(12)

Evaluating the integrals for the inertial classical model (regime 65 °C / 30 min = 1,800 s), where the cooling boundary is tcool_50_classic = root(Tcool_inert(t, 65) − 50, t, 0, 10000) = 2.134 × 103 s (2,134 s):

Nheat_classic = 1.069 × 103,    Nhold_classic = 1.800 × 103,    Ncool_classic = 1.230 × 103
(13)

Total thermal protein damage in the classical water-jacket vat:

Ntotal_classic = Nheat_classic + Nhold_classic + Ncool_classic = 1,069 + 1,800 + 1,230 = 4.099 × 103 units (4,099 units)
(14)

6. Conclusions and Hardware Limitations

Analytical and numerical solution of the coupled integro-differential kinetic equations proves that applying a stationary holding phase (thold > 0) in modern direct-heating batch pasteurizers is a mathematically unfounded and technologically destructive step.

The ratio of objective function values Ntotal_classic / Ntotal_opt = 4,099 / 1,351 ≈ 3.03 demonstrates that transitioning from the inertial hydrodynamics of a water jacket (regime 65 °C / 30 min) to an apparatus with intensified direct heat exchange (optimum 70.00 °C / 0 min) achieves a threefold reduction in chemical protein denaturation (and nearly fourfold on the fast empirical cooling curve) at identical 100% microbiological safety.

The massive thermal protein destruction in a classical jacketed vat is generated by its low heat-transfer criteria, which catastrophically stretch the integration limits, and by the artificial 30-minute stationary hold, which accounts for ≈ 44% of total macromolecular denaturation.

Critical Applicability Limitation: The optimized 70.00 °C / 0 min regime is a direct mathematical function of high heating and cooling velocity gradients dT/dt. Its use is permissible exclusively on equipment technically capable of guaranteeing short transient phases (UZM-E series). Applying the zero-holding algorithm on traditional water-jacket batch pasteurizers is strictly prohibited — their hydrodynamic and thermal inertia will inevitably lead to deviations in microbiological lethality and severe overcooking of the product.

Engineering Selection and Payback Calculation of a Pasteurizer for Your Farm or Dairy Plant

Explore the serial equipment catalog of PE Fomin R.G. with interactive power and payback calculators (direct infrared heating, heat recuperation up to 80 percent, non-fouling SK Special Design):

UZM Milk Pasteurizers (100–3000 L/h) →Milk Pasteurizers for Cheesemaking →Calf Milk Pasteurizers →PS Juice Pasteurizers →