Infrared Milk Pasteurizers-Decontaminators UZM: Operating Experience (Kharchovyk No. 2, 2010)
Infrared Milk Pasteurizers-Decontaminators UZM: Operating Experience
By Dr. Vet. Sci. A. Zavhorodnii (Head of the Tuberculosis Research Laboratory, IECVM NAAS), Ye. Simonov, and R. Fomin (SPE Dairy / PE Fomin R.G.).
1. Selecting Equipment & Preserving Native Whole Milk Properties
One of the most critical moments in milk processing is the selection of equipment. It is essential to carefully draw up the technological scheme and verify whether even a single characteristic of the chosen equipment contradicts it. Whole raw milk is the foundation of foundations; therefore, the closer the product remains in its technological properties to native whole milk after primary thermal treatment, the broader the spectrum of dairy products that can subsequently be manufactured from it. We present for your consideration the infrared milk pasteurization-decontamination unit — UZM.
“Milk from conditionally healthy cows with respect to tuberculosis in an affected farm and from tuberculin-reacting cows in a disease-free farm (during the period of determining the causes of their sensitization to tuberculin) shall be decontaminated by pasteurization in pasteurizers of existing systems at a regime of 85 °C for 30 minutes or at a regime of 90 °C for 5 minutes, and on infrared heating units at a regime of 79.5 °C ± 0.5 °C without holding.” (Instruction on Measures for Prevention and Eradication of Animal Tuberculosis).
All pasteurizers that do not provide the specified decontamination regimes are ordinary commercial pasteurizers and cannot be used for veterinary milk decontamination.
Infrared (IR) milk pasteurization-decontamination units (UZM) are today the only industrial equipment on which milk decontamination takes place at 79.5 °C in continuous flow (without holding time). At lower pasteurization temperatures, the UZM unit operates as an ordinary commercial pasteurizer.
Consequently, if a UZM unit is acquired by a farm affected by tuberculosis or bovine leukosis, the farm will experience zero problems having its milk accepted at a dairy processing plant, because the gentle pasteurization-decontamination regime (79.5 °C without holding) preserves all native technological properties of the product. Both thermal stress and mechanical impact on the milk are reduced to an absolute minimum. Such a farm also completely resolves the problem of safe calf feeding.
If a high-capacity UZM unit is acquired by a dairy processing plant, milk after pasteurization-decontamination can be packaged directly as drinking milk (in terms of product organoleptic characteristics and preservation of vitamin composition, UZM surpasses traditional pasteurization installations while achieving a significantly longer shelf life). Furthermore, from milk that has undergone infrared treatment on UZM, it is possible to manufacture virtually the entire spectrum of fermented sour-milk products, butter, cream, hard cheeses, casein, dry milk powder, and infant nutrition. Production lines for all of the above-listed dairy products are equipped with UZM installations.
The standard commercial pasteurization mode (pasteurization temperature below 79.5 °C) is even less energy-intensive while remaining highly effective for destroying less heat-resistant vegetative microorganisms.
2. Heat Recuperator Formula, Milk Acidity (> 21 °T) & Colostrum Control
Modern pasteurization units may differ in how the product is heated. What they share in common (unless it is a batch long-hold pasteurization vat) is the presence of a plate or tubular heat recuperator (regenerator). It is used to reduce electricity consumption and lower the outlet temperature of the pasteurized product.
When there is a risk of milk with elevated titratable acidity (> 21 °T) or milk with a high colostrum content entering the pasteurization equipment, engineers apply the following inter-stage temperature formula:
where trecup is the product temperature between the heat recuperator and the heating element (°C); tin is the initial inlet temperature of the raw product (°C); qrecup is the heat recuperation coefficient of the heat exchanger; and tpast is the target pasteurization temperature (°C).
If trecup upon substituting the operating data exceeds 68 °C, there is a danger that milk with elevated colostrum content or titratable acidity greater than 21 °T will coagulate inside the recuperator before reaching the heater. The probability of coagulation increases the closer trecup approaches 82 °C. As field experience demonstrates, protein deposits form on the plates in plate recuperators and inside the tubes in tubular recuperators when milk with a high colostrum content or acidity > 21 °T passes through, even under turbulent fluid flow regimes of Re = 9.0 × 103, where Re is the dimensionless Reynolds number.
These raw-material requirements, however, are not extraordinary. Order No. 49 of the State Department of Veterinary Medicine of the Ministry of Agrarian Policy of Ukraine dated April 20, 2004, “On Approval of the Rules of Veterinary and Sanitary Examination of Milk and Dairy Products and Requirements for Their Marketing,” strictly regulates colostrum content and milk acidity in Clauses 3.16 and 7.1 (and for farms processing non-grade colostrum-mixed or high-acidity waste milk for calves, PE Fomin R.G. manufactures dedicated Special Design SK modifications).
The UZM unit is equipped with a plate (or tubular) heat exchanger whose heat recuperation coefficient in the base configuration is 82–89%. Thus, specific energy consumption per ton of milk at qrecup = 83% and tpast = 80 °C is just 12.5 kWh/ton, and at qrecup = 89% it drops to 9 kWh/ton.
3. Technical Specifications of Base UZM Models (Table 1)
| Technical Indicator | UZM-3.0 | UZM-1.0 | UZM-0.5 |
|---|---|---|---|
| Flow Capacity, L/h | 3,000 | 1,000 | 500 |
| Initial Milk Temperature, °C | +6 .. +30 | +6 .. +30 | +6 .. +30 |
| Milk Treatment Temperature, °C: — for tuberculosis — for leukosis — for commercial pasteurization |
80 – 87 80 – 87 70 – 80 |
80 – 87 80 – 87 70 – 80 |
80 – 87 80 – 87 70 – 80 |
| Outlet Product Temperature, °C | +10 .. +40 | +10 .. +40 | +10 .. +40 |
| Installed Power, kW | 36 | 16 | 15 |
| Specific Electricity Consumption per Ton of Milk, kWh/t | 14 … 11 | 15 … 12 | 15 … 12 |
| Unit Weight, kg | 450 | 250 | 250 |
| Occupied Floor Area, m2 | 3 | 2.5 | 2.5 |
| Archive Price (2010 Publication), UAH | 55,000.00 | 35,900.00 | 33,900.00 |
4. Dairy Plant Leasing Model, Thermogram Recording & Phosphatase Control
Table 1 lists the specific energy consumption of UZM units for base equipment configurations. Electricity consumption can be reduced even further by increasing the heat recuperation coefficient. By completing a technical inquiry on www.dairy.kharkov.com, the Customer can determine the exact configuration and cost of a UZM unit for a specified capacity and target energy consumption, or determine energy consumption for a specified capacity and budget.
In recent years, an acquisition model has become popular in which the raw-milk procurement department of a dairy processing plant, seeking to secure a reliable supply of high-grade raw milk, signs supply agreements with partner farms and purchases UZM equipment for them under a leasing arrangement.
The infrared pasteurizer-decontaminator is equipped with automatic control and temperature-regime recording instruments (including the Disk-250 chart recorder and precision digital controllers), guaranteeing strict compliance with the thermal regime and enabling both the receiving dairy plant and state veterinary authorities to audit the supplier.
Because the peroxidase test at such a gentle pasteurization-decontamination temperature (79.5 °C) does not indicate enzyme inactivation, either the milk batch is accompanied by its official pasteurization thermogram, or pasteurization quality is verified via the alkaline phosphatase test, or the pasteurization temperature is set to 87 °C where peroxidase is inactivated.
By the time of this publication, more than 300 UZM installations had been manufactured and placed into service. Over twenty years of engineering experience are at your service.
Head of the Tuberculosis Research Laboratory of IECVM NAAS, Doctor of Veterinary Sciences A. Zavhorodnii; Ye. Simonov, R. Fomin (SPE Dairy / PE Fomin R.G.).