Milk Decontamination Regime for Infrared Pasteurizers — Boundary-Layer Physics & Turbulent Kinetics
Milk Decontamination Regime for Infrared Pasteurizers
Why infrared UZM pasteurizers achieve 100% destruction of Mycobacterium tuberculosis, bovine leukosis, brucellosis, Escherichia coli, Salmonella, foot-and-mouth disease, and mastitis microflora at a bulk milk temperature of 79.5 ± 0.5 °C with zero holding time.
1. Commercial Pasteurization Regimes vs. Veterinary Decontamination
Several thermal regimes are used for milk pasteurization. They differ in pasteurization temperature and exposure time (holding the milk at the target temperature for a specified duration).
Batch pasteurizers (long-hold pasteurization vats, VDP) typically use a regime of 64 ± 1 °C with a holding time of 30–40 minutes. Continuous-flow pasteurizers use regimes with a higher temperature at a shorter exposure. The most widespread commercial flow regimes are:
- 73 ± 1 °C with a holding time of 15–20 seconds;
- 86 ± 1 °C with a holding time of several seconds.
The above pasteurization regimes guarantee the quality of pasteurized drinking milk in accordance with DSTU 2661:2010 “Drinking Cow’s Milk” [1] only if the incoming raw milk entering pasteurization complies with the requirements of DSTU 3662-97 “Whole Raw Cow’s Milk” [2].
Whenever raw milk exceeds permissible limits for total bacterial contamination, or when whole milk contains pathogenic mycobacteria and viruses such as tuberculosis, brucellosis, or foot-and-mouth disease, or when milk is obtained from cows affected by bovine leukosis or mastitis, the standard commercial pasteurization regimes listed above are incapable of decontaminating such milk.
Specifically, pursuant to the official “Instruction on Prevention and Control of Animal Tuberculosis” (Clause 6.1) [3], the veterinary regime for decontaminating milk against tuberculosis mycobacteria requires heating milk to 85 °C with a holding time of 30 minutes, or heating it to 90 °C with a holding time of 5 minutes. It must be emphasized that tuberculosis pathogens (Mycobacterium tuberculosis / bovis) are the most heat-resistant vegetative pathogens in milk; consequently, if a decontamination regime destroys tuberculosis mycobacteria in milk, it simultaneously decontaminates the milk against pathogens of Escherichia coli, bovine leukosis, brucellosis, salmonellosis, and foot-and-mouth disease, as well as microflora in milk obtained from cows with clinical or subclinical mastitis.
In the aforementioned Instruction (Clause 6.1), a separate milk decontamination regime is officially certified that is achievable exclusively by infrared pasteurizers: heating milk to 79.5 ± 0.5 °C without holding time.
A natural engineering question arises: how are infrared pasteurizers so much more effective than all other pasteurizer types? After all, the 79.5 ± 0.5 °C zero-holding decontamination regime is not only highly energy-saving compared to conventional regimes, but also maximally gentle on the technological cheesemaking qualities of milk and its native vitamin composition.
2. Radial Temperature Distribution & Turbulent Boundary-Layer Kinetics
Milk decontamination at a temperature of 79.5 ± 0.5 °C without holding time is achieved thanks to the unique radial temperature distribution inside milk when heated by closed-type infrared heaters and the intense turbulent flow regime of the liquid passing through them.
An infrared heater is a closed-type tubular heating element with outer diameter douter and heat-resistant protective wall thickness ε, inside which milk flows in a turbulent stream, while on the outside an electrical resistance heating element heated by electric current to temperature Telem emits thermal energy in the infrared spectrum directly into the milk flow.
The cross-section and radial temperature profile of such an infrared heater are shown in Figure 1:
The temperature of the inner wall surface of the tubular element Tinner reaches 120 °C, while the penetration depth of infrared radiation into the milk stream εpen is approximately 2 mm. The combined action of convective heat transfer from the wall and volumetric infrared absorption creates within the turbulent milk flow a high-temperature annular boundary layer εpen where the average local milk temperature reaches 105–110 °C. Thanks to the intense turbulent flow regime of the liquid inside the infrared heater, every suspended mycobacterium and bacterial cell is guaranteed to pass through this high-temperature zone with an exposure time of 1.5 to 3 seconds, which guarantees their complete destruction.
Thus, infrared UZM pasteurizers guarantee complete milk decontamination against pathogens of tuberculosis, leukosis, E. coli, brucellosis, foot-and-mouth disease, and salmonellosis, and inactivate the microflora of milk obtained from cows with mastitis, at a bulk pasteurization temperature Tpast = 79.5 ± 0.5 °C without holding time thanks to the residence of mycobacteria inside the infrared penetration zone εpen at a mean local temperature of 105–110 °C for an exposure of 1.5–3 seconds.
R.G. Fomin, Ye.B. Simonov • January 14, 2019