Modern Equipment for Primary Milk Processing: Infrared (IR) Milk Pasteurizers UZM (Kharchovyk No. 2, 2012)
Modern Equipment for Primary Milk Processing: Infrared (IR) Milk Pasteurizers UZM
By Dr. Vet. Sci. A. Zavhorodnii (Head of the Tuberculosis Research Laboratory, IECVM NAAS); R. Fomin, Ye. Simonov (SPE Dairy / PE Fomin R.G.).
1. Primary Milk Processing & Advantages of Farm-Level Infrared Pasteurization
Producing high-quality milk is a labor-intensive and multifactorial process. A mandatory component of primary milk processing is its pasteurization. It can be performed either on the dairy farm or at the dairy processing plant. From an energy-conservation standpoint, it is far more economical to perform pasteurization on the farm prior to cooling.
Two of the most important indicators of milk quality are its titratable acidity and bacterial contamination, which directly determine its commercial grade. Maintaining these indicators at the proper level is especially challenging during the warm season of the year. After milking, raw milk is typically cooled on the farm and dispatched once a day to the dairy plant. Straining milk through a non-woven or lavsan filter pad reduces the amount of mechanical sediment, but practically does not reduce the degree of bacterial contamination. It is impossible to cool milk instantaneously, and the milking process itself lasts 2–3 hours. Once the natural bactericidal phase ends, bacterial contamination and acidity in the milk rise rapidly. Even in milk chilled to 4 °C, the multiplication of microflora continues slowly. The keeping quality (storage stability) of milk at 4–5 °C after infrared pasteurization is substantially superior to that achieved after treatment on traditional pasteurization installations.
By operating an infrared (IR) milk pasteurizer-decontaminator (UZM), a dairy farm earns higher revenue by improving its raw milk grade, while the dairy processor secures high-quality raw material and does not need to pasteurize the milk a second time. UZM is equipment of first necessity for the prevention of tuberculosis and bovine leukosis when feeding calves. The infrared decontamination regime (80 °C without holding time) enables the dairy processing enterprise to use the milk for manufacturing the entire spectrum of dairy products, because infrared pasteurization-decontamination does not alter the native technological properties of milk — whereas traditional high-temperature decontamination (90 °C with a 5-minute hold) makes it impossible to use the milk for manufacturing a wide range of products.
A broad lineup of engineering designs of infrared milk pasteurizers is capable of satisfying any customer requirement and adapting seamlessly to any technological milk production process on the customer’s farm or dairy plant.
2. Technical Specifications of the UZM Lineup (150 to 5,000 L/h)
| Technical Indicators | UZM-0.15 | UZM-0.25 | UZM-0.5 | UZM-1.0 | UZM-1.5 | UZM-3.0 | UZM-5.0 |
|---|---|---|---|---|---|---|---|
| Flow Capacity, L/h | 150 | 250 | 500 | 1,000 | 1,500 | 3,000 | 5,000 |
| Initial Milk Temperature, °C | +4..+30 | +6..+30 | +6..+30 | +6..+30 | +6..+30 | +6..+30 | +6..+30 |
| Milk Treatment Temperature, °C: — for tuberculosis — for leukosis — for standard pasteurization |
79 ± 0.5 79 ± 0.5 70 – 90 |
79 ± 0.5 79 ± 0.5 70 – 80 |
79 ± 0.5 79 ± 0.5 70 – 80 |
79 ± 0.5 79 ± 0.5 70 – 80 |
79 ± 0.5 79 ± 0.5 70 – 80 |
79 ± 0.5 79 ± 0.5 70 – 80 |
— — 70 – 74 |
| Outlet Product Temperature, °C | 15 °C above initial temperature | 15 °C above initial temperature | 10 °C above initial temperature | 10 °C above initial temperature | 10 °C above initial temperature | 9 °C above initial temperature | 8 °C above initial temperature |
| Installed Electrical Power, kW | 6 | 6 | 9 | 16 | 20 | 36 | 50 |
| Unit Weight, kg | 100 | 100 | 150 | 160 | 180 | 250 | 350 |
| Mounting Floor Area, m2 | 3 | 3 | 3 | 3 | 3 | 4 | 4 |