Mon–Sat: 08:00–19:00

Inactivation of Tuberculosis Pathogens in Milk Using an Infrared Electric Heating Pasteurizer (Veterinary Medicine of Ukraine, 1999)

20.09.2022
Scientific Archive • Journal “Veterinary Medicine of Ukraine”, December 1999

Inactivation of Tuberculosis Pathogens in Milk Using an Infrared Electric Heating Pasteurizer

By Yurii Kassich, Andrii Zavhorodnii (Doctors of Veterinary Sciences, IECVM NAAS, Kharkiv); Yevhen Simonov, Volodymyr Pietukhov, Ruslan Fomin (Engineers, Institute of Animal Science NAAS); Volodymyr Horzheiev (First Deputy Head of the State Department of Veterinary Medicine of the Ministry of Agro-Industrial Complex of Ukraine); Vitalii Khomenko (Doctor of Veterinary Sciences), Hennadii Savchuk (Postgraduate Researcher, National Agrarian University); and Viktor Lolia (Head of the Veterinary Medicine Directorate of Kharkiv Regional State Administration).

Published in the journal “Veterinary Medicine of Ukraine”, December 1999

1. Mandatory Decontamination Regimes & Comparative Technical-Economic Indicators

Within the national system of measures for combating cattle tuberculosis, inactivating the tuberculosis pathogen in milk obtained from infected or reacting cows is mandatory. This measure is performed to eliminate the transmission factor of pathogenic mycobacteria through milk from tuberculosis-infected animals to healthy livestock and humans. Under standard veterinary rules, milk is heated to a temperature of 85 °C for 30 minutes or to a temperature of 92 ± 2 °C for 5 minutes on traditional indirect-heating pasteurizers (VDP, OPF-1-300, B6-OP2-F-1), and at a temperature of 79 ± 0.5 °C without holding time on the infrared electric heating milk decontamination (pasteurization) unit.

All regimes for devitalizing tuberculosis pathogens in milk on traditional pasteurization units were developed by the Institute of Experimental and Clinical Veterinary Medicine (I.A. Artiukh et al., 1958; V.K. Mazhar, 1965). The milk pasteurization and decontamination regime on the infrared electric heating unit was determined by the authors of this paper jointly with the inventors of the pasteurizer working at the Institute of Animal Science NAAS (Yu.Ya. Kassich, B.P. Simonov et al., 1986, 1997).

It is well known that the technical and economic indicators of existing pasteurizers vary significantly (see Table).

Technical & Economic Indicator Infrared Electric Heating Pasteurizer (UZM Series) Traditional Pasteurizer B6-OP2-F-1
3000 L/h 2000 L/h 1000 L/h
Flow Capacity, L/h 3,000 2,000 1,000 1,000
Tuberculosis Pathogen Inactivation Temperature, °C 79 ± 0.5 79 ± 0.5 79 ± 0.5 92 ± 2
Milk Holding Time at Target Temperature, s None (0 s) None (0 s) None (0 s) 300
Installed Electrical Power, kW 50 35 20 42.2
Specific Electricity Consumption for Pasteurizing 1 Ton of Milk, kWh/t 15 – 18 15 – 18 15 – 18 53.2
Operating Cost for Pasteurizing 1 Ton of Milk (at 4 Hours/Day Operation), UAH (1999 prices) 7.55 9.20 14.11 17.56
Pasteurizer Mass, kg 450 350 250 1,400

As seen from the table, the infrared electric heating pasteurizer achieves superior technical and economic performance across every parameter.

Furthermore, thanks to the gentle milk pasteurization regime (79 ± 0.5 °C without holding time, rather than 92 ± 2 °C for 5 minutes on indirect-heating pasteurizers), the biochemical and organoleptic quality of milk after pasteurization on the infrared electric heating unit is virtually indistinguishable from fresh milk straight from the cow.

The advantages of this pasteurizer are governed by the specific engineering features of its design, as well as by the energetic, spectral, and hydrodynamic parameters of milk treatment.

2. Farm Dairy Block Technological Line & CIP Operating Phases

The pasteurization process on farm dairy blocks, in accordance with the schematic diagram of the technological line for inactivating tuberculosis pathogens in milk (see Figure), provides for the delivery of raw milk from the milking pipeline or other containers onto milk scales, and then into the milk receiving tank (2). From the receiving tank, milk flows by gravity or is pumped by a sanitary milk pump into the pasteurizer (3), where it is decontaminated in a continuous stream.

The technological milk decontamination unit (highlighted by a dashed boundary on the schematic diagram) comprises:

  • 3a — receiving balance tank equipped with an automatic liquid level regulator;
  • 3b — sanitary centrifugal milk pump;
  • 3v — counter-current plate heat recuperator;
  • 3ye — infrared heating section and automatic control cabinet;
  • 3h, 3d — stainless-steel hydraulic valves with monitoring and control instrumentation.

After decontamination, the milk passes into the cooler (4) and, as needed, is directed into the insulated storage tank (6), where it is held, or is pumped by the transfer pump (7) into a road milk tanker (8).

Operation of the pasteurizer encompasses the following phases of the technological process: initial filling of the hydraulic system with water, thermal sterilization of the system, continuous-flow milk decontamination, and Clean-in-Place (CIP) circulation washing of the pasteurizer with a caustic soda (sodium hydroxide) solution followed by clean water rinsing without disassembling the pasteurizer.

3. Industrial Implementation, Model Range (250 to 3,000 L/h) & Broad Pathogen Eradication

To meet the diverse capacity requirements of milk producers for infrared electric heating pasteurizers, units have been engineered with hourly flow capacities of 250 L, 500, 1,000, 1,500, 2,000, 2,500, and 3,000 liters of milk per hour.

At the time of this 1999 publication, custom infrared electric heating units were manufactured to order by the Scientific-Production Enterprise “Dairy” (Kharkiv Oblast, Kulynychi, Institute of Animal Science; today PE Fomin R.G.). Between 1995 and 1999 alone, this enterprise manufactured 42 industrial units, which were commissioned on commercial dairy farms across 12 regions of Ukraine. In Kharkiv Oblast, 20 infrared pasteurizers operate flawlessly, decontaminating tuberculosis pathogens in whole milk from affected farms as well as in returned skim milk delivered from dairy processing plants for livestock and calf feeding.

Special note should be taken of the universality of the infrared electric heating pasteurizer for inactivating pathogens of various infectious diseases in whole milk and skim milk. On this unit, operators can reliably inactivate pathogens of brucellosis (79 ± 0.5 °C), bovine leukosis, and other infectious diseases in milk. When required by the technological process, high-temperature treatment of milk (up to 95 °C) can also be performed.

With regard to the operational reliability of these pasteurizers, multi-year field experience across Ukrainian farms has demonstrated that when operated in accordance with the instruction manual, they perform flawlessly.

Technological line diagram for milk tuberculosis decontamination on an infrared electric pasteurizer (Veterinary Medicine of Ukraine, Dec 1999)
Schematic diagram of the technological line for continuous-flow milk decontamination on farm dairy blocks (positions 2, 3a–3ye, 4, 6, 7, 8). Original publication in Veterinary Medicine of Ukraine, December 1999, pp. 1–3.

Recommended products