Mon–Sat: 08:00–19:00
Article: УЗМ-1,0

In-Line Infrared Milk Pasteurizer UZM-1.0 (1000 L/h) for Creameries & Mini-Dairies

Available
273 500 грн
  • Nova Post (across Ukraine & Europe)
  • Courier delivery to your door
  • Other freight carriers & direct pickup
  • International shipping: The price includes international transport preparation costs (plastic pallets, cargo lashing straps on the pallet, packaging cardboard, stretch film), customs broker services (export customs clearance), and transport costs for delivering the cargo to the "Nova Post" carrier branch.
  • Bank transfer by official invoice (UAH / EUR / USD)
  • Export price terms: The price includes international transport preparation costs (plastic pallets, cargo lashing straps on the pallet, packaging cardboard, stretch film), customs broker services (export customs clearance), and transport costs for delivering the cargo to the "Nova Post" carrier branch.
  • Cash on delivery or upon pickup
  • Official 12-month manufacturer warranty from PE Fomin R.G.
  • Direct engineering support, commissioning consultation, and spare parts availability

In-Line Infrared Milk Pasteurizer UZM-1.0 (1000 L/h) for Creameries & Mini-Dairies

UZM-1.0 is a high-capacity industrial-grade in-line infrared milk pasteurizer (maximum flow rate 1000 L/h, installed power 21 kW, 100 L receiving buffer tank with automatic level sensors), purpose-built for rapid, gentle, and energy-saving thermal processing of milk in creameries, farmstead mini-dairies, and dairy processing plants.

Economic Rationale: The UZM-1.0 + VDP Cheese Vat Tandem

For many creameries and mini-dairies, large water-jacketed batch vats (500–1000 L VDP cheese vats) are used for both pasteurization and subsequent cheese culturing. However, the multi-hour sequential batch cycle (heating through a high-inertia water jacket, 30-minute hold, and tap-water cooling) limits the plant to 1–2 batches per shift and wastes massive amounts of electricity and water.

Integrating UZM-1.0 in tandem with VDP cheese vats transforms plant productivity. The in-line pasteurizer processes 1000 L in just 60 minutes in continuous flow with up to 80% heat recuperation, delivering pasteurized milk directly into the cheese vat. Freed from jacket heating and cooling cycles, the VDP vat works purely as an insulated culturing & coagulation vat. While curd is forming and being cut in the first vat, UZM-1.0 continuously fills the second and third vats or feeds the cream separator — increasing daily plant output 2–3x.

Process Thermodynamics: Outlet Milk Temperature Across Raw Milk Sources

The base UZM-1.0 model operates on pure recuperative heat exchange, where the outlet pasteurized milk temperature is determined by the inlet raw milk temperature plus the recuperator delta (Δt = +14°C to +22°C depending on flow rate up to 1000 L/h and pasteurization temperature of 75–90°C):

  • Warm Freshly Milked or Pre-Tempered Milk (18–25°C): When supplied with warm milk at 18–25°C, UZM-1.0 discharges pasteurized milk directly at 34–42°C — the ideal temperature window for immediate starter and rennet inoculation in the cheese vat or direct feeding to a milk separator without any additional heating.
  • Chilled Bulk-Tank Milk (4–8°C): When supplied with 4–8°C chilled milk, the pasteurized stream exits the recuperator at 20–26°C. Once pumped into the cheese vat, the vat only needs to gently raise the temperature by 10–14°C to reach culturing temperature (32–38°C), instead of heating from 4°C to 65°C and cooling with tons of water. If your workflow requires a 36–42°C outlet stream directly in continuous flow from 4°C chilled milk without any vat warming, see our industrial model with an integrated boosting heater: UZM-1.0P.

Efficiency Comparison: In-Line UZM-1.0 vs. VDP-1000 Batch Vat System

Comparison Parameter In-Line Pasteurizer UZM-1.0 VDP-1000 Batch Vat System (or 2x VDP-500)
Disinfection Regime 75–90°C (15–20 s in flow) 63–65°C (30 min hold)
Thermal Load on Product Minimal (gentle). Instant IR heating and rapid recuperative cooling preserve native protein structure, vitamins, and calcium balance (maximum cheese yield). Critically high. Prolonged thermal exposure degrades vitamins, denatures whey proteins, and impairs rennet curd coagulation.
Total Processing Time for 1000 L 60 min (in continuous flow) 190 – 240 min
Electricity Consumption (per 1000 L) ~18.0 – 20.0 kWh 75.0 – 95.0 kWh
Cooling Water Consumption for 1000 L 0 L (recuperative cooling by raw milk) ~ 2 500 L

Thermodynamic Comparison Calculator: UZM-1.0 vs. VDP Batch Vat System

Enter milk batch volume, flow rate, and process temperatures for an instant comparative calculation

Efficiency of In-Line UZM-1.0
Recommended Model: UZM-1.0
Installed Power (P_installed): 21.00 kW
Calculated Recuperation Delta (Δt): 16.89 °C
Actual Outlet Temperature (T_in + Δt): 34.9 °C
Pasteurization Cycle:
In-Line Pasteurization Time: 1 h 0 min 0 s
Pasteurization Energy: 18.85 kWh
Total Operating Time: 1 h 0 min 0 s
Cooling Water Consumption: 0 L
Cooling Time: 0 minutes
Actual Electricity Consumed: 18.85 kWh
Energy & Resource Consumption of VDP Batch Vat
Selected Vat Configuration: 1x VDP-1000
Total VDP Heating Element Power (P_VDP): 60.00 kW
Vat Heating Time: 0 min 0 s
Holding Time (30 min): 0 min 0 s
Water-Jacket Cooling Time: 0 min 0 s
Total VDP Process Time: 0 min 0 s
Cooling Water Consumption: 0 L
Heating Electricity (55% efficiency): 0.00 kWh
Economic Benefit of Implementing UZM-1.0: calculating...

Applications of UZM-1.0 in Dairy Processing:

  • Pasteurization for Commercial Cheesemaking: Rapid sequential filling of cheese vats and culturing tanks with pasteurized milk for hard, semi-hard, soft, and brined cheeses, brynza, cottage cheese, and yogurt.
  • In-Line Pasteurization for Milk Separation: Continuous thermal processing of milk fed directly to an industrial cream separator in parallel with cheese vat operations.
  • Pasteurization Prior to Packaging & Storage: Reliable disinfection of raw milk with immediate recuperative cooling before transfer to a bulk cooling tank or bottling line.

Engineering Advantages & Operating Requirements

  • Non-Contact Infrared Heating: Heat transfer in the infrared spectrum eliminates direct contact between milk and red-hot heating elements, preventing protein scorching and preserving natural rennet coagulation properties.
  • Automatic Raw Milk Level Control: The 100 L receiving buffer tank is equipped with upper and lower level sensors, and the control panel includes terminals for connecting an external raw milk feed pump (supplied by the Customer), automating continuous milk supply from an external bulk tank at up to 1000 L/h.
  • Raw Milk Requirements: Do not process colostrum (first 5 days postpartum) or high-acidity milk above 21°T to prevent thermal protein denaturation inside the heat exchanger channels.
  • Closed-Loop CIP Cleaning: At the end of each shift, the entire closed sanitary loop is cleaned without disassembly via circulation (CIP) using standard alkaline and acid solutions through the 100 L receiving tank.
UZM-1.0 (1000 L/h) is a high-return investment in energy efficiency, microbiological safety, and rapid scaling for your creamery or mini-dairy. Contact us to discuss integrating this unit into your production line.

Construction Diagram of Pasteurizer UZM-1.0

Construction diagram and control panel assemblies of in-line pasteurizer UZM-1.0

  1. Control panel;
  2. Pasteurization temperature sensor;
  3. Heat recuperation section;
  4. Digital industrial temperature controller;
  5. Electric contact pressure gauge;
  6. Infrared heating section;
  7. Three-way diverter valve ("circulation" / "discharge" modes);
  8. Flow rate control valve;
  9. Pasteurized milk outlet port;
  10. Pasteurizer milk pump;
  11. 100 L receiving buffer tank;
  12. Upper and lower milk level sensors;
  13. External raw milk feed pump to receiving tank (connection terminal provided on control panel; pump supplied by Customer).

Process Flow Diagram of UZM-1.0

Process flow diagram of milk passing through the recuperator and IR heating section of UZM-1.0

Diagram Legend:

  1. 100 L receiving buffer tank (with automatic level control);
  2. Centrifugal milk pump feeding the pasteurization loop;
  3. Heat recuperation section;
  4. Non-contact IR heating section;
  5. Pasteurization temperature sensor;
  6. Three-way mode diverter valve (circulation / discharge).

PM – outlet of ready pasteurized milk.

Operating Sequence:

  1. Raw milk is fed into the 100 L receiving buffer tank with automatic level control, from which the built-in centrifugal pump delivers a 1000 L/h stream into the heat recuperation section.
  2. In the recuperator, cold raw milk is preheated to ~60–62°C solely by recovering heat from the counter-current stream of hot pasteurized milk (using zero electricity).
  3. The preheated milk then enters the non-contact IR heating section and is heated to the target pasteurization temperature of 75–90°C (maintained automatically by the digital controller).
  4. In the tubular holder, the milk maintains this temperature for 15–20 seconds for complete pathogen destruction.
  5. After holding, the hot stream returns to the recuperation section, transferring its heat to incoming raw milk while cooling down simultaneously.
  6. From the recuperator, pasteurized milk at T_in + (14...22)°C exits (PM) through the three-way valve into your cheese vat, cream separator, or storage tank.

Technical Specifications of UZM-1.0

5 – 90
Parameter Value
Maximum Flow Capacity, L/h 1000
Receiving Buffer Tank Volume, L 100 (with level sensors and external feed pump control)
Installed Power, kW 21
Electricity Consumption (per 1000 L), kWh ~18.0 – 20.0
Pasteurization Temperature, °C
In-Line Holding Time, s 15 – 20
Outlet Milk Temperature, °C T_in + (14...22)
Overall Dimensions (W x D x H), m 1.8 x 1.5 x 1.7

Video Review: UZM In-Line Milk Pasteurizer for Mini-Dairies & Creameries

Video Review Summary:

Engineering analysis and live demonstration of the UZM in-line infrared milk pasteurizer (1000 liters per hour) with a plate heat recuperator operating in tandem with batch cheese vats in a mini-dairy. The UZM unit rapidly pasteurizes milk in continuous flow in the (75–90)/(15–20) regime at 75–90 degrees Celsius (15–20 second hold preserving native whey proteins) and cools it directly to the bacteria inoculation temperature (35–40 degrees Celsius) while saving electricity and water via heat recuperation. Meanwhile, the batch cheese vat is used strictly as an insulated thermos for fermentation and curd processing, enabling the cheesemaker to increase the number of batches processed per shift by 2 to 3 times, with full AQ-teck automation and 15-minute CIP circulation washing.

Video & Photo Gallery — In-Line Infrared Milk Pasteurizer UZM-1.0 (1000 L/h) for Creameries & Mini-Dairies

Be the first to review "In-Line Infrared Milk Pasteurizer UZM-1.0 (1000 L/h) for Creameries & Mini-Dairies"
Write a review
Name
Email
Review
Rate the product on a 5-point scale
Your rating:
Thanks for your review!

Viewed Products