Mon–Sat: 08:00–19:00
Article: УЗМ-500

In-Line Infrared Milk Pasteurizer UZM-500 (500 L/h) for Mini-Dairies

Available
221 600 грн
  • Nova Post (across Ukraine & Europe)
  • Courier delivery to your door
  • Other freight carriers & direct pickup
  • International shipping: The price includes international transport preparation costs (plastic pallets, cargo lashing straps on the pallet, packaging cardboard, stretch film), customs broker services (export customs clearance), and transport costs for delivering the cargo to the "Nova Post" carrier branch.
  • Bank transfer by official invoice (UAH / EUR / USD)
  • Export price terms: The price includes international transport preparation costs (plastic pallets, cargo lashing straps on the pallet, packaging cardboard, stretch film), customs broker services (export customs clearance), and transport costs for delivering the cargo to the "Nova Post" carrier branch.
  • Cash on delivery or upon pickup
  • Official 12-month manufacturer warranty from PE Fomin R.G.
  • Direct engineering support, commissioning consultation, and spare parts availability

In-Line Infrared Milk Pasteurizer UZM-500 (500 L/h) for Mini-Dairies

UZM-500 is a compact, high-efficiency in-line infrared milk pasteurizer (500 L receiving tank, 500 L/h actual pump flow rate, 18 kW installed power), purpose-built for rapid, gentle, and energy-saving thermal processing of milk in mini-dairies, craft creameries, and farmstead cheese workshops.

Economic Rationale: The UZM-500 + VDP Cheese Vat Tandem

For many mini-dairies and craft creameries, a water-jacketed batch vat (VDP cheese vat) serves a dual purpose: pasteurizing milk and subsequently culturing/coagulating it into cheese, brynza, cottage cheese, or yogurt. However, the slow sequential batch cycle (long heating through a water jacket, 30-minute holding, and slow tap-water cooling) severely bottlenecks daily output to 1–2 batches per shift while consuming excessive electricity and cooling water.

Pairing UZM-500 in tandem with VDP cheese vats transforms the economics of your creamery. The in-line pasteurizer takes over the entire thermal duty: it instantaneously pasteurizes and cools the milk in continuous flow using up to 80% heat recuperation, filling the VDP vat with ready-to-culture milk at the exact inoculation temperature (e.g., 32–40°C). If the required outlet temperature exceeds the sum of the inlet raw milk temperature plus the recuperation delta, the unit performs a rapid closed-loop circulation preheating pass through its 500 L receiving tank. Freed from heating and cooling duties, your VDP vat operates purely as an insulated culturing & coagulation vat — multiplying daily plant throughput while saving up to 70% electricity and 100% cooling water.

Efficiency Comparison: In-Line UZM-500 vs. Batch VDP-500

Comparison Parameter In-Line Pasteurizer UZM-500 Batch Pasteurizer VDP-500
Disinfection Regime 75–90°C (15–20 s in flow) 63–65°C (30 min hold)
Thermal Load on Product Minimal (gentle). Instant IR heating and rapid recuperative cooling preserve native protein structure, vitamins, and calcium balance (maximum cheese yield). Critically high. Prolonged thermal exposure degrades vitamins, denatures whey proteins, and impairs rennet curd coagulation.
Total Processing Time for 500 L ~60 – 75 min (in continuous flow, pump rate 500 L/h) 180 – 210 min
Electricity Consumption (per 500 L) 15.0 – 18.0 kWh 52.5 – 70.0 kWh
Cooling Water Consumption for 500 L 0 L (recuperative cooling by raw milk) ~ 1250 L

Thermodynamic Comparison Calculator: UZM-500 vs. VDP Batch Vat System

Enter process flow temperatures for an instant comparative calculation

Efficiency of In-Line UZM-500
Recommended Model: UZM-500
Installed Power (P_installed): 18.00 kW
Calculated Recuperation Delta (Δt): 0.00 °C
Circulation Preheating Loop: none
Preheating Time: 0 min 0 s
Preheating Energy Consumption: 0.00 kWh
In-Line Pasteurization Time: 0 min 0 s
Total Operating Time: 0 min 0 s
Cooling Water Consumption: 0 L
Cooling Time: 0 minutes
Actual Electricity Consumed: 0.00 kWh
Energy & Resource Consumption of VDP Batch Vat
Selected Vat Configuration: VDP Batch Vat
Total VDP Heating Element Power (P_VDP): 0.00 kW
Vat Heating Time: 0 min 0 s
Holding Time (30 min): 0 min 0 s
Water-Jacket Cooling Time: 0 min 0 s
Cooling Water Consumption: 0.00 L
Total VDP Process Time: 0 min 0 s
Cooling Water Consumption: 0 L
Heating Electricity (55% efficiency): 0.00 kWh
Savings per 500 L batch: -- kWh | -- L of water | -- of time

Applications of UZM-500 in Dairy Processing:

  • Pasteurization for Cheesemaking & Culturing: Rapidly fills cheese vats and culturing tanks with pasteurized milk at the exact starter and rennet inoculation temperature (32–40°C) for soft, brined, semi-hard, and hard cheeses, brynza, cottage cheese, or yogurt.
  • In-Line Pasteurization for Milk Separation: Continuous thermal processing with a 40–45°C outlet stream fed directly to a cream separator while a previous batch is coagulating in the cheese vat.
  • Pasteurization Prior to Bottling: Reliable disinfection of raw milk with immediate recuperative cooling in continuous flow before transfer to a bulk cooling tank or bottling line.

Engineering Advantages & Operating Requirements

  • Non-Contact Infrared Heating: Heat is transferred to the milk stream in the infrared spectrum without direct contact with red-hot heating elements, completely preventing protein scorching and caramelized off-flavors.
  • Circulation Preheating Loop: Using the three-way diverter valve ("circulation" / "discharge" modes), the operator can pre-warm a batch of cold 4–8°C milk through the 500 L receiving tank whenever a higher outlet temperature (35–42°C) is needed for cheesemaking.
  • Raw Milk Requirements: Do not process colostrum (first 5 days postpartum) or high-acidity milk above 21°T.
  • Closed-Loop CIP Cleaning: The entire sanitary loop is cleaned rapidly without disassembly via circulation (CIP) using standard alkaline and acid dairy detergents fed through the 500 L receiving tank.
UZM-500 (500 L/h) is an investment in energy efficiency, microbiological safety, and scalable output for your craft creamery or mini-dairy. Contact us to discuss integrating this unit into your workflow.

Construction Diagram of Pasteurizer UZM-500

Construction diagram and control panel of in-line pasteurizer UZM-500

  1. Heat recuperation section;
  2. Temperature sensor;
  3. Infrared heating section;
  4. Control panel;
  5. Akutek digital industrial temperature controller;
  6. Three-way diverter valve ("circulation" / "discharge" modes);
  7. Electric contact pressure gauge;
  8. Bimetallic thermometer;
  9. Flow rate control valve;
  10. Sanitary milk pump;
  11. Receiving tank, 500 L.

Process Flow Diagram of UZM-500

Process flow diagram of milk passing through the recuperator and heating section of UZM-500

Diagram Legend:

  1. Receiving tank, 500 L;
  2. Centrifugal milk pump;
  3. Heat recuperation section;
  4. Non-contact IR heating section;
  5. Pasteurization temperature sensor;
  6. Three-way mode diverter valve (circulation / discharge).

PM – outlet of ready pasteurized milk.

Operating Sequence:

  1. Milk from the receiving tank (500 L) is fed by the centrifugal milk pump at a flow rate of 500 L/h into the heat recuperation section.
  2. If the target outlet temperature exceeds the sum of the inlet milk temperature plus the recuperation delta, the three-way valve is set to "circulation" for rapid preheating of the batch through the receiving tank.
  3. In pasteurization mode, cold raw milk is preheated in the recuperator to ~60°C solely by recovering heat from the counter-current stream of hot pasteurized milk (using zero electricity).
  4. The milk then enters the IR heating section (18 kW), where it is heated to 75–90°C (automatically maintained by the Akutek digital controller).
  5. In the built-in tubular holder, the milk maintains the pasteurization temperature for 15–20 seconds for complete pathogen inactivation.
  6. After holding, the hot stream returns to the recuperation section, transferring its heat to incoming raw milk while cooling down to culturing temperature, and exits (PM) through the three-way valve into your cheese vat or receiving vessel.

Technical Specifications of UZM-500

5 – 90
Parameter Value
Rated Batch Capacity, L 500
Actual Flow Rate (Pump Capacity), L/h 500
Installed Power, kW 18
Electricity Consumption (per 500 L), kWh 15.0 – 18.0
Pasteurization Temperature, °C
In-Line Holding Time, s 15 – 20
Outlet Milk Temperature, °C 35 – 50 (or T_in + recuperation Δt)
Overall Dimensions (W x D x H), m 2.1 x 1.3 x 1.7

Video Review: UZM In-Line Milk Pasteurizer for Mini-Dairies

Video Review Summary:

Engineering analysis and live demonstration of the UZM in-line infrared milk pasteurizer (100–1000 liters per hour) with a heat recuperator operating in tandem with batch cheese vats in a mini-dairy. The UZM unit rapidly pasteurizes milk in continuous flow in the (75–90)/(15–20) regime at 75–90 degrees Celsius (15–20 second hold preserving native whey proteins) and cools it directly to the bacteria inoculation temperature (35–40 degrees Celsius) while saving electricity and water via heat recuperation. Meanwhile, the batch cheese vat is used strictly as an insulated thermos for fermentation and curd processing, enabling the cheesemaker to increase the number of batches processed per shift by 2 to 3 times, with full AQ-teck automation and 15-minute CIP circulation washing.

Video & Photo Gallery — In-Line Infrared Milk Pasteurizer UZM-500 (500 L/h) for Mini-Dairies

Be the first to review "In-Line Infrared Milk Pasteurizer UZM-500 (500 L/h) for Mini-Dairies"
Write a review
Name
Email
Review
Rate the product on a 5-point scale
Your rating:
Thanks for your review!

Viewed Products